Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.
The RBP is 14 atm (1419 kPa) for all balloons except the 200 and 250 mm balloons. For the 200 and 250 mm balloons the RBP is 11 atm (1115 kPa). The RBP is based on the results of in vitro testing. Use of pressures higher than RBP may result in a ruptured balloon with possible intimal damage and dissection. The safety and effectiveness of using ...
The ACTIVE (Use of the Assurant® Cobalt Iliac Stent System in the Treatment of Iliac Vessel Disease) Study Using the Medtronic Assurant Cobalt Iliac Balloon-Expandable Stent System: Study Start Date : October 2008: Actual Primary Completion Date : February 2011: Actual Study Completion Date : September 2013
Avance del tratamiento de la enfermedad periférica de la arteria, Medtronic, Inc. (NYSE: MDT) anunció hoy la aprobación por los E.E.U.U
Assurant Cobalt Iliac Stent Affected / at Risk (%) # Events Total : 37/123 (30.08%) Cardiac disorders : CARDIAC ... Medtronic has a legitimate interest in ensuring that a multi-center publication is the first publication to be released regarding the completed Study. The Institution agrees that it will not publish or disclose any results of or ...
Medtronic, Inc. (Minneapolis, MN) announced that the US Food and Drug Administration has approved the company's Assurant Cobalt Iliac stent sys-tem for the treatment of narrowed iliac arteries. The device features a bal-loon-expandable stent made from a cobalt chromium alloy. Approval was
Découvrez toutes les informations sur le produit : stent artère iliaque Assurant Cobalt® de la société Medtronic. Contactez un fournisseur ou directement la maison mère pour connaître le prix, obtenir un devis et découvrir les points de vente près de chez vous.
I served as the quality core team member for the Assurant Cobalt Iliac balloon expandable stent delivery system during design phases 3 & 4. On-load site Quality Assurance representative for technology transfer of endovascular stent graft delivery system operations to the Galway site, which included significant process validation and test method ...
In Stock! Ships Today! $99.00 box of 1 - Medtronic Vascular # ASC930SV - Medtronic Assurant Cobalt Iliac Balloon-Expandable OTW Stent System: 9mm x 30mm x 80cm
Medtronic's Assurant Cobalt Iliac Balloon expendable stent system is designed to provide radial strength and imaging compatibility. The 6 F sheath has compatibility across complete size matrix (6-10 mm). According to the manufacturer, minimal …
The assurant cobalt stent was protruding into aorta and the stent leading edge/struts opened prior to deployment. The stent could not be re-sheathed and the stent could not be advanced. The stent was deployed as a u shape between left and right iliacs and the stent now covers bifurcation.
In the ACTIVE study [25], the balloon-expandable Assurant® cobalt-chromium iliac stent demonstrated primary patency at 9 months of 99.2 %, device and lesion success were each 97.5 % (155/159 ...
In Stock! Ships Today! $99.00 box of 1 - Medtronic Vascular # ASC1040SV - Medtronic Assurant Cobalt Iliac Balloon-Expandable OTW Stent System: 10mm x 40mm x 80cm
Encuentre toda la información del producto: stent arteria ilíaca Assurant Cobalt® de la empresa Medtronic. Póngase en contacto con un proveedor o con la empresa matriz directamente para conocer los precios, obtener un presupuesto y descubrir los puntos de venta más cercanos.
Group capital expenditures for tangible and intangible assets increased by 2.2% to EUR 121.8 million during 1Q 06 compared to the same period last year. Net debt decreased by EUR 136.3 million to EUR 2,977.4 million at the end of March 2006, compared to EUR 3,113.7 million at the end of December 2005.
Company Name: MEDTRONIC, INC.. Brand Name: ASSURANT® COBALT. Global Unique Device ID: 006. Version (Model) Number: ASC720LV. Device Name: Stent ASC720LV AssrntCo 7mmx20mmx130cm. Company Name: MEDTRONIC, INC.. Brand Name: ASSURANT® COBALT. Request Dataset ... MEDTRONIC, INC. Company name associated with the labeler DUNS Number ...
Assurant® Cobalt Iliac Stent Features Novel Alloy and Modular Design Augments Company's Peripheral Portfolio with Balloon Expandable Option MINNEAPOLIS –– Advancing the treatment of peripheral artery disease, Medtronic, Inc. today announced approval by the U.S. Food and Drug Administration (FDA)
ASSURANT COBALT (PAD) Assurant Cobalt®。。 :,。
In Stock! Ships Today! $99.00 box of 1 - Medtronic Vascular # ASC1030LV - Medtronic Assurant Cobalt Iliac Balloon-Expandable OTW Stent System: 10mm x 30mm x 130cm
Medtronic stated that the Assurant cobalt stent demonstrated exceptional technical, procedural, and clinical success in the trial and had low rates of major adverse events, target lesion revascularization (TLR) and target vessel revascularization (TVR)—all at 0.8%. In addition, the device also achieved a 99.2% primary patency rate with one of ...
Medtronic's Assurant Cobalt Iliac Balloon expendable stent system is designed to provide radial strength and imaging compatibility. The 6 F sheath has compatibility across complete size matrix (6-10 mm). According to the manufacturer, minimal foreshortening provides precise stent...
1. Device DescriptionThe Medtronic Assurant ® Cobalt Balloon Expandable Over-the-Wire(OTW) Stent System consists of a cobalt-chromium alloy stent premountedon an over-the-wire balloon catheter delivery system. Thestent delivery system catheter has two radiopaque markers mountedon the catheter at the proximal and distal end of the stent to aid in theplacement of the stent.
A physician was attempting to deploy an assurant cobalt balloon expandable peripheral stent to treat a lesion in the left subclavian with 90% and moderate calcification. The lesion was pre-dilated. It was reported that the assurant cobalt device was advanced to the lesion but was unable to cross the lesion.
Balloon angioplasty and stenting are the two most common ways to treat blocked arteries without open surgery. Percutaneous (through the skin) transluminal angioplasty (PTA) balloons come in various sizes, lengths and shapes, depending on the anatomy they're intended to treat. Stents are small, expandable metal mesh tubes that hold arteries open.
Medtronic Assurant Cobalt® Iliac (8 mm x 60 mm) Boston Scientific Express® LD (8 mm x 57 mm) *Bench data on file at Medtronic, Inc., compares the Assurant Cobalt Iliac stent with the Boston Scientific Express® LD stent and Abbott Omnilink Elite® stent. Bench test results may not be indicative of clinical performance.
R&D Engineer on the Assurant Cobalt iliac stent delivery system project. Involved in initial concept generation through to product launch. Project managed a new serialised labelling system for the Assurant Cobalt ACTIVE clinical trial.
Please use one of the following formats to cite this article in your essay, paper or report: APA. Medtronic. (2019, June 18). O FDA aprova o stent do …
Principal Peripheral Sales Representative at Medtronic. Dallas, Texas, United States 179 connections. Join to Connect ... -Award Recognition- Highest Assurant Cobalt Sales in the United States
In Stock! Ships Today! $99.00 box of 1 - Medtronic Vascular # ASC640SV - Medtronic Assurant Cobalt Iliac Balloon-Expandable OTW Stent System: 6mm x 40mm x 80cm
Brand Name: ASSURANT® COBALT Version or Model: ASC860SV Commercial Distribution Status: In Commercial Distribution Catalog Number: Company Name: MEDTRONIC, INC. Primary DI Number: 006 Issuing Agency: GS1 Commercial Distribution End Date: Device Count: 1 Labeler D-U-N-S® Number*: ...
The Assurant Cobalt stent leverages the strength of cobalt chromium and a unique modular design to create a device with ultrathin, round, edgeless struts, allowing for smooth delivery to …
The Minneapolis-area medical device giant said its Assurant cobalt-chromium iliac stent found favor at the watchdog agency. Medtronic touts the …